WEKO3
アイテム
{"_buckets": {"deposit": "94dbe60c-c821-4332-acd4-69b10f902ff7"}, "_deposit": {"created_by": 3, "id": "19242", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "19242"}, "status": "published"}, "_oai": {"id": "oai:twinkle.repo.nii.ac.jp:00019242", "sets": ["1989"]}, "author_link": ["296207", "296209", "296203", "296202", "296205", "296200", "296208", "296206", "296204", "296201"], "item_10001_alternative_title_1": {"attribute_name": "別タイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Development and Evaluation of a New Stent (Eigorotta Yamachicchi Stent) for Magnetic Compression Anastomosis"}]}, "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "284", "bibliographicPageStart": "280", "bibliographicVolumeNumber": "74", "bibliographic_titles": [{"bibliographic_title": "東京女子医科大学雑誌"}]}]}, "item_10001_creator_2": {"attribute_name": "著者名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "町田, 治彦"}], "nameIdentifiers": [{"nameIdentifier": "296200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山内, 栄五郎"}], "nameIdentifiers": [{"nameIdentifier": "296201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "杉浦, 孝司"}], "nameIdentifiers": [{"nameIdentifier": "296202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池田, 隆久"}], "nameIdentifiers": [{"nameIdentifier": "296203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三橋, 紀夫"}], "nameIdentifiers": [{"nameIdentifier": "296204", "nameIdentifierScheme": "WEKO"}]}]}, "item_10001_date_25": {"attribute_name": "受付日付", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2010-08-10", "subitem_date_issued_type": "Created"}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Initial success rate of magnetic compression enteroenteric anastomosis is high, but acute stenosis occurred unfavorably sometimes. If magnets migrate too early from the anastomosis, mucosal defects cause ulceration leading to cicatricial contraction and acute stenosis. To prevent this problem, we developed the Eigorotta Yamachicchi (EY) Stent The EY Stent consists of a pair of cylindrical stents, each with a rare earth disc magnet and a small flange. Upon completion of anastomosis, resistance occurs at both ends of the flanges and the mated stents are thought to retain longer at the anastomosis. We performed magnetic compression gastro-duodenal anastomosis by oral insertion of the EY Stent to six dogs. Three dogs were killed after two weeks and the other three dogs after four weeks. In the two-week group, we found that the Stents retained and ulcers at the anastomosis were identified. In the four-week group, the Stents were excreted before the dogs were killed and complete mucosal unions were confirmed. Leak-free anastomosis was formed in both groups. Compared with our other compression gastro-duodenal anastomosis dog experiments using ordinary magnets, the EY Stents retained longer and complete mucosal unions at the anastomosis were found. The result suggests that the newly developed EY Stents could be useful in preventing acute stenosis after enteroenteric anastomosis.", "subitem_description_type": "Abstract"}]}, "item_10001_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "296205", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "MACHIDA, Haruhiko"}]}, {"nameIdentifiers": [{"nameIdentifier": "296206", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "YAMANOUCHI, Eigoro"}]}, {"nameIdentifiers": [{"nameIdentifier": "296207", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "SUGIURA, Takashi"}]}, {"nameIdentifiers": [{"nameIdentifier": "296208", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "IKEDA, Takahisa"}]}, {"nameIdentifiers": [{"nameIdentifier": "296209", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "MITSUHASHI, Norio"}]}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京女子医科大学学会"}]}, "item_10001_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00161368", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0040-9022", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_subject_47": {"attribute_name": "著者キーワード", "attribute_value_mlt": [{"subitem_subject": "Eigorotta Yamachicchi Stent", "subitem_subject_scheme": "Other"}, {"subitem_subject": "enteroenteric magnetic compression anastomosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "acute stenosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "experimental dog model", "subitem_subject_scheme": "Other"}]}, "item_10001_text_35": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京女子医科大学医学部放射線医学教室"}, {"subitem_text_value": "聖マリアンナ医科大学横浜市西部病院放射線科"}, {"subitem_text_value": "大阪大学医学部生体情報医学講座"}, {"subitem_text_value": "東京医科大学外科学第三講座"}, {"subitem_text_value": "東京女子医科大学医学部放射線医学教室"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-08-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00006018867.pdf", "filesize": [{"value": "1.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1800000.0, "url": {"label": "KJ00006018867.pdf", "url": "https://twinkle.repo.nii.ac.jp/record/19242/files/KJ00006018867.pdf"}, "version_id": "7cea1e75-fa5a-4047-9312-6c5be3e5d14f"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "磁石圧迫吻合ステント(Eigorotta Yamachicchi Stent)の開発とその評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "磁石圧迫吻合ステント(Eigorotta Yamachicchi Stent)の開発とその評価"}]}, "item_type_id": "10001", "owner": "3", "path": ["1989"], "permalink_uri": "http://hdl.handle.net/10470/26541", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-08-10"}, "publish_date": "2010-08-10", "publish_status": "0", "recid": "19242", "relation": {}, "relation_version_is_last": true, "title": ["磁石圧迫吻合ステント(Eigorotta Yamachicchi Stent)の開発とその評価"], "weko_shared_id": -1}
磁石圧迫吻合ステント(Eigorotta Yamachicchi Stent)の開発とその評価
http://hdl.handle.net/10470/26541
http://hdl.handle.net/10470/265417d8df3f9-6076-45eb-9630-94e7459a7efb
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00006018867.pdf (1.8 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-08-10 | |||||
タイトル | ||||||
タイトル | 磁石圧迫吻合ステント(Eigorotta Yamachicchi Stent)の開発とその評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
別タイトル | ||||||
その他のタイトル | Development and Evaluation of a New Stent (Eigorotta Yamachicchi Stent) for Magnetic Compression Anastomosis | |||||
著者名 |
町田, 治彦
× 町田, 治彦× 山内, 栄五郎× 杉浦, 孝司× 池田, 隆久× 三橋, 紀夫 |
|||||
著者別名 | ||||||
姓名 | MACHIDA, Haruhiko | |||||
著者別名 | ||||||
姓名 | YAMANOUCHI, Eigoro | |||||
著者別名 | ||||||
姓名 | SUGIURA, Takashi | |||||
著者別名 | ||||||
姓名 | IKEDA, Takahisa | |||||
著者別名 | ||||||
姓名 | MITSUHASHI, Norio | |||||
出版者 | ||||||
出版者 | 東京女子医科大学学会 | |||||
受付日付 | ||||||
日付 | 2010-08-10 | |||||
日付タイプ | Created | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0040-9022 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00161368 | |||||
書誌情報 |
東京女子医科大学雑誌 巻 74, 号 5, p. 280-284, 発行日 2004-05 |
|||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Initial success rate of magnetic compression enteroenteric anastomosis is high, but acute stenosis occurred unfavorably sometimes. If magnets migrate too early from the anastomosis, mucosal defects cause ulceration leading to cicatricial contraction and acute stenosis. To prevent this problem, we developed the Eigorotta Yamachicchi (EY) Stent The EY Stent consists of a pair of cylindrical stents, each with a rare earth disc magnet and a small flange. Upon completion of anastomosis, resistance occurs at both ends of the flanges and the mated stents are thought to retain longer at the anastomosis. We performed magnetic compression gastro-duodenal anastomosis by oral insertion of the EY Stent to six dogs. Three dogs were killed after two weeks and the other three dogs after four weeks. In the two-week group, we found that the Stents retained and ulcers at the anastomosis were identified. In the four-week group, the Stents were excreted before the dogs were killed and complete mucosal unions were confirmed. Leak-free anastomosis was formed in both groups. Compared with our other compression gastro-duodenal anastomosis dog experiments using ordinary magnets, the EY Stents retained longer and complete mucosal unions at the anastomosis were found. The result suggests that the newly developed EY Stents could be useful in preventing acute stenosis after enteroenteric anastomosis. | |||||
著者所属 | ||||||
東京女子医科大学医学部放射線医学教室 | ||||||
著者所属 | ||||||
聖マリアンナ医科大学横浜市西部病院放射線科 | ||||||
著者所属 | ||||||
大阪大学医学部生体情報医学講座 | ||||||
著者所属 | ||||||
東京医科大学外科学第三講座 | ||||||
著者所属 | ||||||
東京女子医科大学医学部放射線医学教室 | ||||||
著者キーワード | ||||||
主題Scheme | Other | |||||
主題 | Eigorotta Yamachicchi Stent | |||||
著者キーワード | ||||||
主題Scheme | Other | |||||
主題 | enteroenteric magnetic compression anastomosis | |||||
著者キーワード | ||||||
主題Scheme | Other | |||||
主題 | acute stenosis | |||||
著者キーワード | ||||||
主題Scheme | Other | |||||
主題 | experimental dog model |