{"created":"2023-06-20T16:58:12.165962+00:00","id":16862,"links":{},"metadata":{"_buckets":{"deposit":"806ae581-c9bc-4ef6-80c8-3a13b21a3adc"},"_deposit":{"created_by":3,"id":"16862","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"16862"},"status":"published"},"_oai":{"id":"oai:twinkle.repo.nii.ac.jp:00016862","sets":["140:1307:1308:1912:1923"]},"author_link":["260860","260857","260858","260859","260861","260856"],"item_10001_alternative_title_1":{"attribute_name":"別タイトル","attribute_value_mlt":[{"subitem_alternative_title":"Management of Glaucoma by Optic Disc Auto-Analyzer"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-12-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"12","bibliographicPageEnd":"1053","bibliographicPageStart":"1049","bibliographicVolumeNumber":"67","bibliographic_titles":[{"bibliographic_title":"東京女子医科大学雑誌"}]}]},"item_10001_creator_2":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩切, 玉代"}],"nameIdentifiers":[{"nameIdentifier":"260856","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"土坂, 寿行"}],"nameIdentifiers":[{"nameIdentifier":"260857","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金, 恵媛"}],"nameIdentifiers":[{"nameIdentifier":"260858","nameIdentifierScheme":"WEKO"}]}]},"item_10001_date_25":{"attribute_name":"受付日付","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-08-10","subitem_date_issued_type":"Created"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"New equipment for analyzing the ocular fundus was developed to automatically determine the index of optic nerve head damage, and its clinical efficacy was evaluated. The subjects were 42 eyes in 26 patients with ocular hypertension or open-angle glaucoma ranging in age from 25 to 88 years old. Change in the index, which shows the optic nerve damage and visual field in each eyes was evaluated over a period of 4 to 22 months (mean: 11.1 months). The results of the last examinations with the equipment in 38 eyes with 24 patients were similar to those obtained at the first examination. The index of 4 eyes in 2 patients was more than 15% worse, and in these cases, visual field defects developed. The results showed that the equipment is useful as a method of measuring for the clinical evaluation of glaucoma.","subitem_description_type":"Abstract"}]},"item_10001_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"260859","nameIdentifierScheme":"WEKO"}],"names":[{"name":"IWAKIRI, Tamayo"}]},{"nameIdentifiers":[{"nameIdentifier":"260860","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TSUCHISAKA, Hisayuki"}]},{"nameIdentifiers":[{"nameIdentifier":"260861","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KIN, Keien"}]}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"東京女子医科大学学会"}]},"item_10001_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN00161368","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0040-9022","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_35":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京女子医科大学眼科学教室"},{"subitem_text_value":"東京女子医科大学眼科学教室"},{"subitem_text_value":"西新井病院眼科"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-03-27"}],"displaytype":"detail","filename":"KJ00006025292.pdf","filesize":[{"value":"455.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00006025292.pdf","url":"https://twinkle.repo.nii.ac.jp/record/16862/files/KJ00006025292.pdf"},"version_id":"ecb54271-5414-496b-8e87-d207886bc0de"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"視神経乳頭所見の自動解析装置による緑内障の管理","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"視神経乳頭所見の自動解析装置による緑内障の管理"}]},"item_type_id":"10001","owner":"3","path":["1923"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-08-10"},"publish_date":"2010-08-10","publish_status":"0","recid":"16862","relation_version_is_last":true,"title":["視神経乳頭所見の自動解析装置による緑内障の管理"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T23:02:00.148018+00:00"}